ecma418-torch

Newly released project. First published on GitHub on 2026-10-11 (version 0.1.0 in its metadata); no release or PyPI package yet. Not yet seen to be widely used in the community. Check its validation before relying on it.

Roughness (Clause 7) and fluctuation strength (Clause 9) of ECMA-418-2:2025 (4th edition) in PyTorch, differentiable end to end, with the binaural combination of two channels. The code cites the formula numbers of the standard and lists the places where it reads a printed formula differently.

Repositoryhttps://github.com/agrathwohl/ecma418-torch
Documentationhttps://github.com/agrathwohl/ecma418-torch#readme
LanguagePython
KindLibrary/Toolbox
Functions to call from your own code: a Python package, a MATLAB toolbox, or a C, C++, C#, Rust or Julia library.
Groupnewly released First released less than about a year ago, and not yet seen to be widely used in the community.
LicenceMIT
Latest releaseno release
Last commit2026-10-11 active
MaintainersAndrew Grathwohl
AI assistancenot stated
How to citeThe project does not say how to cite it. Cite the repository with the version or commit you used.
Entry checked17 October 2026

What it implements

MetricEditionFunctionsValidation (as stated)Notes
Sottek Hearing Model roughnessECMA-418-2:2025 (4th ed.)
with binaural combination; without the optional entropy weighting of Section 7.1.6
roughnesscompared with sottek-hearing-model and ArtemiS SUITE (HEAD acoustics)new
Sottek Hearing Model fluctuation strengthECMA-418-2:2025 (4th ed.)
with binaural combination
fluctuation_strengthcompared with sottek-hearing-model and ArtemiS SUITE (HEAD acoustics)new

How it was validated

As reported by the project; LISQM has not run the code. Two implementations that agree can still share the same error. Kinds of evidence.

Sottek Hearing Model roughness · ECMA-418-2:2025 (4th ed.)

compared with sottek-hearing-model and ArtemiS SUITE (HEAD acoustics)

  • The 1 kHz tone amplitude-modulated at 70 Hz (60 dB SPL) gives 0.9999987 asper for 10 s (the test allows 1e-4 around 1), and the average specific roughness in band 17 is 0.37348, against 0.374 from ArtemiS v17 as quoted in the tests of sottek-hearing-model.
  • Against sottek-hearing-model run as an oracle on three signals (the calibration tone, noise and a mixture of modulated tones and noise), the time-dependent values differ by at most 2e-5 asper and the single values by at most 2e-5; the README traces the residual to the rounded filter coefficients.
  • The tests also check that two identical channels give the mono result and that input at 44.1 kHz gives the 48 kHz result within 0.2 %.
Sottek Hearing Model fluctuation strength · ECMA-418-2:2025 (4th ed.)

compared with sottek-hearing-model and ArtemiS SUITE (HEAD acoustics)

  • The 1 kHz tone amplitude-modulated at 4 Hz (60 dB SPL) gives 0.99579 vacil for 10 s (the test allows 1e-2 around 1), and the average specific fluctuation strength in band 17 is 0.38876, against 0.395 from ArtemiS v17 as quoted in the tests of sottek-hearing-model.
  • Against sottek-hearing-model run as an oracle on two signals: with that package's three choices, the time-dependent values differ by at most 6.3e-5 vacil and the single values by at most 6.3e-5; with the defaults, which follow the printed text, the single values differ by 0.2 % and 0.5 %.

Before you compare numbers

Implementations of the same metric can give different numbers without either being wrong. Check these choices first.

For single metrics:

Sottek Hearing Model fluctuation strength (ECMA-418-2:2025 (4th ed.))
  • By default it follows the printed text in three places where sottek-hearing-model decides otherwise: the step limit of Formula (152) (2e-4 Hz, against 0.2), no fundamental required for an assumed order in Section 9.1.8, and machine epsilon for ε0 (against 1e-12). The options newton_cap and require_fundamental give sottek-hearing-model's choices.
  • Formula (127) is computed with π instead of the printed 2π in the phase term, and Formula (144) without the printed "− 1", which the code says would shift every rate down one bin.

Notes

Before you rely on it

Sources

  1. https://github.com/agrathwohl/ecma418-torch/blob/master/README.md
  2. https://github.com/agrathwohl/ecma418-torch/blob/master/LICENSE
  3. https://github.com/agrathwohl/ecma418-torch/blob/master/pyproject.toml
  4. https://github.com/agrathwohl/ecma418-torch/blob/master/benchmarks/evidence.md
  5. https://github.com/agrathwohl/ecma418-torch/blob/master/tests/test_fidelity.py
  6. https://github.com/agrathwohl/ecma418-torch/blob/master/tests/fixtures/make_oracle_fixtures.py
  7. https://github.com/agrathwohl/ecma418-torch/blob/master/src/ecma418_torch/fluctuation.py